Summary
This tab of the Options for PCB Project dialog enables you to specify the output path and related options for generated outputs for the project. You can also specify various netlisting options and the Net Identifier Scope.
Access
This is one of multiple tabs available when configuring the options for a project – accessed from within the Options for PCB Project dialog. This dialog is accessed by:
- Clicking Project | Content | , from the main menus in the Schematic Editor, or the PCB Editor.
- Right-clicking on the entry for the project itself, on the Projects panel, and choosing Project Options from the context menu.
Options/Controls
- Ouput Path - the default output path for generation of output files from the current design project (*.PrjPcb) or when compiling packaged libraries (in a *.LibPkg) as an integrated library.
- ECO Log Path - the default output path for ECO log files.
- Schematic Template Location - use this field to specify a directory in which to source schematic template files (*.SchDot, *.SchDoc) for the project.
Output Options
- Open outputs after compile - enable this option to open files that were generated from compiling the design project.
- Timestamp folder - enable this option to create a timestamp folder for generated output. The folder name is in the format <FolderName> Date Time where the <FolderName> is specified in the Output Path field, and Date and Time are in the same format as your System settings.
- Archive project document -
- Use separate folder for each output type - enable this option to create separate folders for each output type generated for the design project. If you have opted to create a timestamp folder, separate folders will be created under that folder.
Netlist Options
- Allow Ports to Name Nets - enable this option to name a net using the Name property of a wired port, rather than using a default, system-generated net name.
- Allow Single Pin Nets - enable this option to allow the existence of nets containing only a single pin.
- Append Sheet Numbers to Local Net - enable this option to append the value for a schematic document's Sheet Number parameter (a document-level parameter) to nets that are local to that sheet. A local net is a net that does not leave the sheet. For a net that does leave the sheet (and is therefore not local), this option does not apply.
- Higher Level Names Take Priority - enable this option to have the net labels used on higher sheets in the hierarchy, name the nets on the lower sheets.
- Power Port Names Take Priority - the software has the ability to localize a global power net, by wiring a power port to a normal port. This would force all pins on that sheet, connected to that power port, to be in a separate net. Enabling this option would force net naming using the name of the net assigned to the power port.
Net Identifier Scope
Multi-sheet designs are defined at the electrical (or connective) level by Net Identifiers. Net identifiers (net labels, ports, sheet entries, power ports, hidden pins) create logical connections between points in the same net. This can be within a sheet, or across multiple sheets. Physical connections exist when one object is attached directly to another electrical object by a wire. Logical connections are created when two net identifiers of the same type (e.g. two net labels) have the same Net property.
When the connectivity model of the design is created, you must define how you want net identifiers to connect to each other – this is known as setting the Net Identifier Scope. There are essentially two ways of connecting sheets in a multi-sheet design: either horizontally, directly from one sheet, to another sheet, to another sheet, and so on; or vertically, from a sub-sheet to the sheet symbol that represents it on the parent sheet. In horizontal connectivity, the connections are from port to port (net label to net label is also available). In vertical connectivity, the connections are from sheet entry to port.
Use the drop-down list presented here to choose from the following scopes:
- Automatic (Based on project contents) - this mode automatically selects which of the net identifier modes to use based on the following criteria: if there are sheet entries on the top sheet, then Hierarchical is used; if there are no sheet entries, but there are ports present, then Flat is used; if there are no sheet entries and no ports, then Global is used.
- Flat (Only ports global) - ports connect globally across all sheets throughout the design. With this option, net labels are local to each sheet; they will not connect across sheets. All ports with the same name will be connected, on all sheets. This option can be used for flat multi-sheet designs. It is not recommended for large designs as it can be difficult to trace a net through the sheets.
- Hierarchical (Sheet entry <-> port connections, power ports global) - connect vertically between a port and the matching sheet entry. This option makes inter-sheet connections only through sheet symbol entries and matching sub-sheet ports. It uses ports on sheets to take nets or buses up to sheet entries in corresponding sheet symbols on the parent sheet. Ports without a matching sheet entry will not be connected, even if a port with the same name exits on another sheet. Net labels are local to each sheet; they will not connect across sheets. Power ports are global however – all power ports with the same name are connected throughout the entire design. This option can be used to create designs of any depth or hierarchy and allows a net to be traced throughout a design on the printed schematic.
- Strict Hierarchical (Sheet entry <-> port connections, power ports local) - this mode of connectivity behaves in the same way as the Hierarchical mode, with the only difference being that power ports are kept local to each sheet; they will not connect across sheets to power ports of the same name.
- Global (Netlabels and ports global) - ports and net labels connect across all sheets throughout the design. With this option, all nets with the same net label will be connected together, on all sheets. Also, all ports with the same name will be connected, on all sheets. If a net connected to a port also has a net label, its net name will be the name of the net label. This option can also be used for flat multi-sheet designs, however it is difficult to trace from one sheet to another, since visually locating net names on the schematic is not always easy.
Allow Pin-Swapping Using These Methods
In the PCB editor, Pin, Differential Pair and Part swaps are performed by exchanging nets on component pads and their corresponding copper. When the changes are merged into the schematics there are two ways that a pin swap can be handled:
- Adding / Removing Net-Labels - enable this option to allow swapping of pins on a component symbol. Performing the swap on the schematic by swapping net labels can only be done if the connectivity is established through the net labels, that is, if the pins are not hard-wired together.
- Changing Schematic Pins - enable this option to allow swapping of net labels on the wires attached to the pins of a component. Swapping Pins will be the only option available when nets have been physically hardwired to a component. This method can be used on simple components (such as a resistor arrays) or where there is no alternative because of the structure of the schematic design.